Página 1 - Specication guide

Specication guideHeating

Página 2 - About this guide

10 | Rinnai Heating Specication Guide 02-13Energysaver 309FT Energysaver 561FT Energysaver 559FT Energysaver 1004FTRColour White with grey louv

Página 3

Rinnai Heating Specication Guide 02-13 | 11Rinnai Energysaver 559FT Rinnai Energysaver 1004FTRRinnai Energysaver 561FTEnergysaver dimensions (m

Página 4 - Heating range

12 | Rinnai Heating Specication Guide 02-13Energysaver ueing guidelinesIt is the responsibility of the installer to ensure that the appliance

Página 5 - detail

Rinnai Heating Specication Guide 02-13 | 13Energysaver ueing optionsFLUEING OPTION DESCRIPTION FLUE COMPONENTS NEEDEDDirect and direct extende

Página 6 - Location considerations

14 | Rinnai Heating Specication Guide 02-13Energysaver ue componentsDirect AA mushroom flue kitCode = R1350For use in walls 75-115 mm thick (

Página 7

Rinnai Heating Specication Guide 02-13 | 15Ø 75120Ø 8012045 ° flue bends (x2)Code = ESBENDTwo 45 ° bends used to facilitate between horizontal,

Página 8 - Product

16 | Rinnai Heating Specication Guide 02-13Condensate trapCode = ESCONDKRequired for any vertical installations to ensure condensate generated

Página 9 - Energysavers

Rinnai Heating Specication Guide 02-13 | 17Portable Convectors (unued)Rinnai Portable Convector codesGas Type Dynamo AvengerNG RCE471TRWHN RC

Página 10 - SENSITIVE

18 | Rinnai Heating Specication Guide 02-13Dynamo RCE471 Avenger RCE671Colour White with grey louvres White with grey louvresEfficiency* 100% 100

Página 11 - Energysaver dimensions (mm)

Rinnai Heating Specication Guide 02-13 | 19Portable Convector accessoriesWall socket stainless steelCode = R2580WSFlush wall socket stainless

Página 12 - Energysaver ueing guidelines

This guide has been written to help you select and order the right Rinnai heating system and associated components for the right job. This information

Página 13 - Energysaver ueing options

20 | Rinnai Heating Specication Guide 02-13Super RaysRinnai Super Ray codesGas Type Indoor Super Ray 16 Indoor Super Ray 24 Indoor Super Ray 4

Página 14 - Direct A mushroom flue kit

Rinnai Heating Specication Guide 02-13 | 21Super Ray specication summaryIndoor Super Ray 16 Indoor Super Ray 24 Indoor Super Ray 40 Outdoor Su

Página 15 - External wall plate

22 | Rinnai Heating Specication Guide 02-13Super Ray clearance informationOutdoor Super Ray1800 mm from floor500 mm from wall or other materials

Página 16 - Elbow adaptor

Rinnai Heating Specication Guide 02-13 | 23Multiple heater positioning for total area heatingHeaters can be positioned side by side or facing e

Página 17 - LPG RCE471TRWHL RCE671TRWHL

24 | Rinnai Heating Specication Guide 02-13Indoor Super Ray accessories: Heat shieldRinnai Indoor Super Ray heat shield codesIndoor Super Ray 1

Página 18

Rinnai Heating Specication Guide 02-13 | 25Indoor Super Ray accessories: Deluxe surroundRinnai Indoor Super Ray deluxe surround codesIndoor Sup

Página 19 - Mushroom hose 10 mm

26 | Rinnai Heating Specication Guide 02-13Rinnai iHeatRinnai iHeat central heating codeRAHU20DescriptionThe Rinnai iHeat is a ducted home heat

Página 20 - Super Rays

Rinnai Heating Specication Guide 02-13 | 27Rinnai iHeat specication summaryRinnai iHeatEnergy efficiency Approximately the same as the Rinnai IN

Página 21

28 | Rinnai Heating Specication Guide 02-13Rinnai iHeat accessoriesRinnai iHeat fittings kitCode = R5046Designed to simplify and speed up the i

Página 22 - 1800 mm

Rinnai heatingAppendices

Página 23

cnt:Heating range ...4Choosing the right type of heating ...

Página 24 - WHS16 WHS24 WHS40

30 | Rinnai Heating Specication Guide 02-13Appendix 1: Running costsRunning costs can play an important part in the purchase decision. Based on

Página 25 - R1446 R1447 R1448

Rinnai Heating Specication Guide 02-13 | 31Rinnai iHeat running costsRunning costs for the Rinnai iHeat are still being collated as we are tryi

Página 26 - 750 mm min

32 | Rinnai Heating Specication Guide 02-13Appendix 2: Calculating the minimum room sizeUnflued heaters must not be installed in rooms smaller t

Página 27

Rinnai Heating Specication Guide 02-13 | 33Appendix 3: Energysaver 1004FTR remote wiring diagramRemote switching kit: R1347. Rinnai does not su

Página 28 - Rinnai iHeat fittings kit

34 | Rinnai Heating Specication Guide 02-13Appendix 4: Denition of an outdoor areaThis appliance shall only be used in an above ground open ai

Página 30 - Appendix 1: Running costs

Rinnai.co.nz Experience our innovation 0800 746 624http://www.youtube.com/rinnainz

Página 31

4 | Rinnai Heating Specication Guide 02-13Heating rangeRinnai provide fast and reliable heating. Hallmarks of our product range are precise tem

Página 32

Rinnai Heating Specication Guide 02-13 | 5Choosing the right type of heatingConsiderations such as geographical location, room size, room insul

Página 33 - Rinnai Energysaver

6 | Rinnai Heating Specication Guide 02-13Location considerationsThe following general guidelines should be factored when deciding on where to

Página 34

Rinnai Heating Specication Guide 02-13 | 7Rinnai iHeat®: Determining suitabilitySpending time in the planning stages and discussing the heating

Página 35

Rinnai heating solutionsProduct specication pages

Página 36 - Experience our innovation

Rinnai Heating Specication Guide 02-13 | 9EnergysaversRinnai Energysaver® codesGas Type Energysaver 309FT Energysaver 561FT Energysaver 559FT E