Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do no
10 VA Series Indoor LS Manual Setting the Water Volume 1. Press the “Priority button” on the temperature controller. The green Priority light will
VA Series Indoor LS Manual 11 Filling the Tub 1. Press the “Water Smart / Bath Fill” button once. The button will illuminate, a tone will sound,
12 VA Series Indoor LS Manual WARNING Turn off the electrical power supply, the manual gas valve and the manual water control valve whenever se
VA Series Indoor LS Manual 13 Error Codes The Rinnai water heater has the ability to check its own operation continuously. If a fault occurs, an
14 VA Series Indoor LS Manual 14 Thermal Fuse Check gas type of unit and ensure it matches gas type being used. Check for restrictions in air flow
VA Series Indoor LS Manual 15 Trouble Shooting for Common Issues I don,t have any hot water when I open the tap. Make sure there
16 VA Series Indoor LS Manual Flushing the Heat Exchange (Error Code: LC or 00) An “LC” or “00” error code indicates the unit is beginnin
VA Series Indoor LS Manual 17 Only properly trained and qualified installers should install this appliance. The warranty may be voided due to imp
18 VA Series Indoor LS Manual to Combustibles to Non-Combustibles R50LSi R75LSi R94LSi R98LSiTop of Heater 6 inches (152 mm) 12 inches (305 mm)
VA Series Indoor LS Manual 19 Gas Piping General Instructions A manual gas control valve must be placed in the gas supply
2 VA Series Indoor LS Manual Specifications ...3 Consumer Safety Information Safety Definitions
20 VA Series Indoor LS Manual Pipe Sizing Procedure - Example 1. Determine the cubic feet per hour of gas required by dividing the gas input (on th
VA Series Indoor LS Manual 21 Water Piping A manual water control valve must be placed in the water inlet connection to the
22 VA Series Indoor LS Manual This is not an engineered drawing, it is intended only as a guide andnot as a replacement for professionally engineere
VA Series Indoor LS Manual 23 Recommended Piping for Basic Installation GasSupply3/4"ColdWaterSupplyLine3/4" Hot Water Sup
24 VA Series Indoor LS Manual Recommended Piping for Circulation Systems This is not an engineered drawing, it is intended only as a gu
VA Series Indoor LS Manual 25 Optional Piping for Circulation Systems This is not an engineered drawing, it is intended only as a g
26 VA Series Indoor LS Manual • Vertical terminations must incorporate a condensate drain and trap as close as possible to the appliance. • Slope
VA Series Indoor LS Manual 27 Example: If you have one elbow then your maximum vent length is 35 feet (10.7 m). If your actual length is greater
28 VA Series Indoor LS Manual Vent Products Manufacturer Product Parts Rinnai/Ubbink Rolux Vent System Heat-Fab Saf-T Vent SC system Metal-Fab C
VA Series Indoor LS Manual 29 Flue Terminal Clearances (ANS Z21.10.3 • C SA 4.3) INSIDECORNER DETAI LFIXEDCLOSEDOPERABLEFIXEDCL
VA Series Indoor LS Manual 3 Specifications R50LSi R75LSi R94LSi R98LSi R98LSi-ASME Minimum Gas Consumption Btu/h 15,000 19,000 Maximum Gas Con
30 VA Series Indoor LS Manual 24"V Additional Clearances - Vent Terminal Local codes supersede these clearances. Avoid terminati
VA Series Indoor LS Manual 31 Flue Installation - Concentric Venting (R50LSi, R75LSi, R94LSi) 3 in (75 mm) minimum Condensate Trap Vertic
32 VA Series Indoor LS Manual Air Intake Assembly The air intake system consists of a field supplied 4 inch diameter stainless steel, Schedule 40 PV
VA Series Indoor LS Manual 33 Vertical Terminations The air intaThe vent termination and air intake must be in the same pressure zone.ke requires
34 VA Series Indoor LS Manual High Altitude Installations 12345678ONFFOSwitch No.12345678ONFFOSwitch No.12345678ONFFOSwitch No.123
VA Series Indoor LS Manual 35 The controller should be out of reach of small children. Avoid locations where the controller may become hot (near th
36 VA Series Indoor LS Manual 1. Determine a suitable location for the controller. 2. Make three holes in the wall as shown. 3. Run the cable betw
VA Series Indoor LS Manual 37 Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING A. This appliance does not have a p
38 VA Series Indoor LS Manual Water Flow Rate (gpm)Pressure Loss (psi) 0102030405060708090104540353025201510500Pressure Loss (ft head)0255075100 125
VA Series Indoor LS Manual 39 Space Heating If the water heater is to be used for both water (potable) heating and space heat
4 VA Series Indoor LS Manual WARNING Safety Behavior and Practices Keep the area around the appliance clear and free from co
40 VA Series Indoor LS Manual Dimensions ABCDKIJGFHEDIM DESCRIPTIONR50LSiR75LSiR94LSiin (mm) R98LSi R98LSi-ASME in (mm) A Wi
VA Series Indoor LS Manual 41 Ladder Diagram RELAY 1IGFROST SENSINGSWITCHANTI-FROST HEATERIGNITIONCOMBUSTIONFAN3A(FUSE)HOTNEUT
42 VA Series Indoor LS Manual Consumer Support What is covered? This Warranty covers any defects in materials or workmanship when the product is ins
VA Series Indoor LS Manual 43 Limited Warranty Continued What will Rinnai do? Rinnai will repair or replace the covered produc
Rinnai America Corporation 103 International Drive Peachtree City, GA 30269 TOLL FREE: 1-800-621-9419 FAX: 678-829-1666 www.rinnai.us Rinnai’s other f
VA Series Indoor LS Manual 5 The Rinnai water heater is one of the most advanced water heaters available. It provides a continuous supply of hot
6 VA Series Indoor LS Manual TemperatureDisplayThermostatPriorityIndicatorPriorityButtonON/OFFButtonIn UseIndicatorTemperatureDisplayThermostatIn Use
VA Series Indoor LS Manual 7 TemperatureDisplayThermostatIn UseIndicatorPriority Buttonand IndicatorON/OFFButtonClockCallFunctionTemperatureDispla
8 VA Series Indoor LS Manual Setting the Temperature 1. Press the “Priority button” on the temperature controller. The Priority
VA Series Indoor LS Manual 9 Temperature Ranges This water heater will attempt to provide hot water at the temperature setting