Rinnai RHFE-556T Instruções de Operação

Consulte online ou descarregue Instruções de Operação para Aquecedores elétricos Rinnai RHFE-556T. Rinnai RHFE-556T Operating instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 40
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Energysaver
RHFE-556FTR
Customer
page 2
Installer
page 21
CONTENTS
Warranty ..........................1
Layout of appliance..........2
Features...........................5
Safety Points ....................7
Operation .........................9
Adjusting Temperature...10
Economy Mode ..............10
Child Lock ......................11
Humidifier.......................12
Clock ..............................13
ON/OFF Timers .............14
Override .........................17
Remote Control..............17
Extension Kits ................34
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1 - RHFE-556FTR

Energysaver RHFE-556FTRCustomerpage 2Installerpage 21CONTENTSWarranty ...1Layout of appliance...2Features...

Página 2 - RINNAI WARRANTY OF QUALITY

– 9 –OPERATING YOUR NEW RHFE-556FTR TO OPEN THE CONTROL PANELLift lightly in the centre of the lid where there isa catch. The control panel lid will

Página 3 - Certification Body

– 10 – ROOM TEMPERATURE ADJUSTMENT ECONOMY MODEThe room temperature and pre-set temperatures can only be displayed and adjusted when the heater isru

Página 4 - CONTROL PANEL LAYOUT

– 11 – CHILD PROOF LOCK AUTO COMFORTA room temperature sensor located at the rear of the appliance is continuously monitoring the temperatureof the

Página 5 - REMOTE CONTROL

– 12 – FAN FILTERTo protect the room air fan from dust particles or lint, afilter is situated at the rear of the appliance. Whenthis filter becomes

Página 6 - FEATURES

– 13 –SETTING THE CLOCKThis Heater has an Integral Time Clock but can also be installed as part of a centrally controlled Time ClockSystem.To set-up t

Página 7 - PRE-SET

– 14 –PROGRAMMING THE TIMER(S)Before programming the Timers you must ensure that the clock has been set to the correct time. See page 13.TIMER 2 is p

Página 8 - SAFETY POINTS

– 15 –OPERATING THE TIMER(S)Before operating the Timer(s), the clock time must be correct, and a starting time and finishing time forthe Timer(s) must

Página 9

– 16 –PRE-HEATThe Pre-heat function will heat a room to the pre-set temperature by the programmed On Time.1This function operates automatically in con

Página 10 - ■ TURNING OFF

– 17 –OVERRIDE FUNCTIONUSING THE REMOTE CONTROLThis function is intended to be used to manually override the current operation of the heater, Forexam

Página 11 - ■ ECONOMY MODE

– 18 –CARING FOR YOUR NEW RHFE-556FTRThis appliance is controlled by a micro computer. If there is something wrong with the appliance thenit will sto

Página 12 - ■ AUTO COMFORT

– 1 –RINNAI WARRANTY OF QUALITYAs the purchaser of this high quality model RHFE-556FTR product you are provided with the followingwarranty:Free PartsH

Página 13 - ■ VERTICAL LOUVRE ADJUSTMENT

– 19 –PRE-SERVICE CHECKBefore asking for a service call please check the following points.These points are part of the normal operation of the unit.

Página 14 - SETTING THE CLOCK

– 20 –ERROR MESSAGESThe Energysaver 556FTR has the ability to check its own operation continuously. If a fault occurs, anError Message will flash on

Página 15 - PROGRAMMING THE TIMER(S)

– 21 –INSTALLATION INSTRUCTIONSIMPORTANT SAFETY INFORMATION1. Gas Safety (Installation & Use). Regulations 1998 are the ‘Rules in Force’.In your

Página 16 - SET AND FORGET OPERATION

– 22 –INSTALLATION INSTRUCTIONSSPECIFICATIONInput 6.4Kw (21840 Btu/h) Burner: Stainless Bunsen TypeIgnition: Continuous Spark Gas Inlet: 1/2 inch BSP

Página 17 - PRE-HEAT

– 23 –LOCATIONWhen positioning the heater the main pointsgoverning the location are:1. Flueing2. Warm air distributionThis heater must not be installe

Página 18 - USING THE REMOTE CONTROL

– 24 –LOCATIONDo not flue into natural draught flues or fireplaces,this unit can only be used with one of the six typesof Rinnai flue kits.Do not flue

Página 19

– 25 –POSITIONING THE FLUE TERMINALOHNNMQMHKBPQQIFLJGCAID,EDimensionABCDEFGHIJKLMNOPQTerminal PositionDirectly below an opening, air brick, opening wi

Página 20 - PRE-SERVICE CHECK

– 26 –LOCATIONDo not install the heater in an unusually dusty area.Use a flue guard if the terminal is easily accessibleto children.Check local regula

Página 21 - ERROR MESSAGES

– 27 –SLEEVE AND MANIFOLD INSTALLATIONMETHOD FOR STANDARD WALLS1. Dis-assemble Manifold from Sleeve.The flue consists of 3 parts, sleeve, insideconnec

Página 22 - IMPORTANT SAFETY INFORMATION

– 28 –SLEEVE AND MANIFOLD INSTALLATIONMETHOD FOR STANDARD WALLS5. Check rubber seal is in place on terminal.6. Installation of TerminalFrom outside, i

Página 23 - SPECIFICATION

– 2 –GETTING TO KNOW YOUR NEW RHFE-556FTRREMOTE CONTROLBRACKETROOMTEMPERATURESENSORGAS CONNECTIONELECTRICAL CORDHUMIDIFIER TRAYBuilt into the warm air

Página 24 - LOCATION

– 29 –FITTING UNITAIR INLET HOSELOCKING CLAMP, SCREW CLAMP ANDINSULATION.The following components can be fitted by reachingdown the rear of the applia

Página 25

– 30 –CONNECTING GAS AND ELECTRICAL SERVICES1. GAS CONNECTION.Purge any air or swarf from the gas line. Connect up the appliance to the gas supply us

Página 26 - POSITIONING THE FLUE TERMINAL

– 31 –TESTINGPRESSURE CHECKING PROCEDURECaution – 230V inside appliance1. Check that SW6 (Dip switches) are correct for the gastype for which the appl

Página 27

– 32 –FITTING TOP SPACER + WALL CLIP SECURE HEATER TO WALLFix angle bracket to back spacer with screwsprovided.Fix wall bracket to wall, so that the

Página 28 - METHOD FOR STANDARD WALLS

– 33 –BLOCK AND WIRING DIAGRAMWIRING DIAGRAMBLOCK DIAGRAMSW6, DIP SWITCHTB1SUB-P.C.BSW1 FM, ADJUST SWITCH〔Hi〕 SW2 FM, ADJUST SWITCH〔Lo〕 SW3 POV, P

Página 29

– 34 –• This extension set is to be used for installations requiring extra distance.MAXIMUM FLUE LENGTH 4.5m WITH 3 ELBOWS NAMES AND NUMBERS OF PARTS

Página 30 - FITTING UNIT

– 35 – TYPES COMPATIBLE WITH EXTENSION KITRHFE-556FTR/556TINSTALLING AN EXTENSION KITInstalling an extension kit requires construction of an air line

Página 31

– 36 –1. How to connect exhaust pipesTo connect the exhaust pipes, fit the male end into the female end and clamp with pipe stopper A toprevent slippi

Página 32 - SW6 DIP SWITCH

– 37 – CAUTIONS1. Maximum extendable lengthFOR BEST ROOM AIR HUMIDITY, KEEPWATER IN THE HUMIDIFIER TRAY.2. To prevent water condensationCondensed wat

Página 33 - FAULT-FAILURE PROCEDURE

– 38 –4. Wherever the air intake hose and exhaust piperun sideways, try to have the exhaust pipe ontop (to prevent the air intake hose from saggingont

Página 34 - BLOCK DIAGRAM

Child LockTimer 1EconomyTimer 2 OverrideAMPMSet  RoomTemp・ TimeSet timesClockTimer 1Timer 2Filter on offON / OFFON・ – 3 –CONTROL PANEL LAYOUTECONOM

Página 35 - ■ NAMES AND NUMBERS OF PARTS

– 39 –556F-219101 / 06DIMENSIONSSERVICE CONTACT POINT30050214R279R206217 245632750WALL OPENING RANGEAIR SUPPLY CONNECTION5542802807785165GAS CONNECTIO

Página 36 - ■ HOW TO INSTALL

– 4 –REMOTE CONTROLONOFFOFF BUTTONStops heater manually.TEMPERATUREADJUSTMENTIncreases or decreasesthe temperature setting. ON BUTTONOper

Página 37

– 5 –FORCED FLUE SYSTEM PUSH BUTTON IGNITIONAir for combustion is taken from outside theroom and the flue products are exhaustedoutside, keeping the r

Página 38 - ■ CAUTIONS

– 6 –MEMORYThe micro-computer records selected pre-set temperatures, the times programmedinto Timers as well as operating theEconomy and Intelligent m

Página 39 - Air intake hose

– 7 –SAFETY POINTSDo not restrict the warm air discharge byplacing articles in front of the heater.This appliance must not be used for anypurpose othe

Página 40 - SERVICE CONTACT POINT

– 8 –SAFETY POINTSKeep flammable materials, trees, shrubs, etc,away from the flue terminal.Do not allow anyone to post articles throughthe louvres.LPG

Comentários a estes Manuais

Sem comentários