Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
Operation and Installation Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Table of Contents .................... 2
Consumer Safety Information .. 4
Operating Instructions .............. 5
Maintenance ............................ 12
Error Codes ............................. 13
Installation Instructions ............ 17
Consumer Support ................... 40
French Version ........................ 42
Direct Vent Tankless Water Heater
Register your product at www.rinnairegistration.com or
call 1-866-RINNAI1 (746-6241)
ANS Z21.10.3
CSA 4.3
FOR INDOOR APPLICATIONS ONLY
RC80HPi ............. REU-KA2530FFUD-US
RC98HPi ............. REU-KA3237FFUD-US
FOR OUTDOOR APPLICATIONS ONLY
RC80HPe ............ REU-KA2530WD-US
RC98HPe ............ REU-KA3237WD-US
Vista de página 0
1 2 3 4 5 6 ... 59 60

Resumo do Conteúdo

Página 1

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

Página 2 - Table of Contents

10 Manual - Rinnai Condensing Water Heaters Setting the Water Volume 1. Press the “Priority” button. 2. Press the “Water Smart Bath Fill” button t

Página 3 - Specifications

Manual - Rinnai Condensing Water Heaters 11 Setting Controller to Mute To eliminate the beeps when keys are pressed or to turn th

Página 4 - Consumer Safety Information

12 Manual - Rinnai Condensing Water Heaters WARNING Turn off the electrical power supply, the manual gas valve and the manual water control val

Página 5 - Operating Instructions

Manual - Rinnai Condensing Water Heaters 13 Error Codes The Rinnai water heater has the ability to check its own operation continuously. If a fau

Página 6

14 Manual - Rinnai Condensing Water Heaters Code Fault Remedy 16 Over Temperature Warning Check for restrictions in air flow around unit and vent

Página 7

Manual - Rinnai Condensing Water Heaters 15 Trouble Shooting for Common Issues I don’t have any hot water when I open the tap. M

Página 8

16 Manual - Rinnai Condensing Water Heaters Flushing the Heat Exchanger (Error Code: LC or 00) An “LC” or “00” error code indicates the un

Página 9 - (Voice Prompt)

Manual - Rinnai Condensing Water Heaters 17 Only properly trained and qualified installers should install this appliance. The warranty may be voi

Página 10 -

18 Manual - Rinnai Condensing Water Heaters Clearances from Appliance 1. Identify the installation location and confirm that the in

Página 11

Manual - Rinnai Condensing Water Heaters 19 Gas Piping General Instructions • A manual gas control valve must be placed in

Página 12 - WARNING

2 Manual - Rinnai Condensing Water Heaters Specifications ... 3 Consumer Safety Information Safe

Página 13 - Error Codes

20 Manual - Rinnai Condensing Water Heaters Pipe Sizing Procedure - Example 1. Determine the cubic feet per hour of gas required by dividing the ga

Página 14

Manual - Rinnai Condensing Water Heaters 21 The freeze protection features include electrical heating elements. Freeze protection may be disabled

Página 15

22 Manual - Rinnai Condensing Water Heaters If the water heater is not going to be used during a period of possible freezing weather, it is recommen

Página 16

Manual - Rinnai Condensing Water Heaters 23 Recommended Piping for Basic Installation GasSupply3/4"ColdWaterSupplyLine3/4"

Página 17 - Installation Instructions

24 Manual - Rinnai Condensing Water Heaters Recommended Piping for Circulation Systems Pressure Relief Valve3/4" Ball Valve3/4"

Página 18

Manual - Rinnai Condensing Water Heaters 25 Optional Piping for Circulation Systems Pressure Relief Valve3/4" Ball Valve3/4&qu

Página 19

26 Manual - Rinnai Condensing Water Heaters Venting Instructions • This water heater is a direct vent water heater and therefore

Página 20

Manual - Rinnai Condensing Water Heaters 27 Example: If you have one elbow then your maximum vent length is 35 feet (10.7 m). If your actual len

Página 21

28 Manual - Rinnai Condensing Water Heaters Flue Terminal Clearances (ANS Z21.10.3 ● CSA 4.3) INSIDECORNER DETAILFIXEDCLOSEDOPERABLEF

Página 22

Manual - Rinnai Condensing Water Heaters 29 24"V Additional Clearances - Vent Terminal (RC80HPi, RC98HPi) Local codes supersede thes

Página 23 - Refer to the Condensate

Manual - Rinnai Condensing Water Heaters 3 Specifications Rinnai is continually updating and improving products. Therefore, specifications are su

Página 24

30 Manual - Rinnai Condensing Water Heaters 2"36"12"INSIDECORNER Additional Clearances (RC80HPe, RC98HPe) Local codes super

Página 25 - (To eliminate cold water

Manual - Rinnai Condensing Water Heaters 31 Flue Installation (RC80HPi, RC98HPi) Secure the first vent component to the water heater

Página 26

32 Manual - Rinnai Condensing Water Heaters High Altitude Installations 0-2000 ft (0-610 m) 2001-5200 ft (610-1585 m) 5201-7700 f

Página 27 - Switch No

Manual - Rinnai Condensing Water Heaters 33 Temperature Controller Installation • The controller should be out of reach of smal

Página 28

34 Manual - Rinnai Condensing Water Heaters Temperature Controller Installation 1. Determine a suitable location for the controll

Página 29 - 12"

Manual - Rinnai Condensing Water Heaters 35 Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING A. This appliance doe

Página 30 - 36"

36 Manual - Rinnai Condensing Water Heaters Technical Data Pressure Drop Curve Outlet Flow Data RC98HP Water

Página 31 - Vertical Termination

Manual - Rinnai Condensing Water Heaters 37 Space Heating If the water heater is to be used for both water (potable) heating

Página 32

38 Manual - Rinnai Condensing Water Heaters Dimensions DIM DESCRIPTION RC80HPi in (mm) A Width 18.5 (470) B Depth 10.5 (26

Página 33 - Controllers

Manual - Rinnai Condensing Water Heaters 39 Ladder Diagram WATER LEVEL DETECTING CIRCUIT WATER LEVEL ELECTRODE TWIN THERMISTO

Página 34

4 Manual - Rinnai Condensing Water Heaters WARNING Safety Behavior and Practices • Keep the area around the appliance clear

Página 35 - Manual Valve

40 Manual - Rinnai Condensing Water Heaters What is covered? This Warranty covers any defects in materials or workmanship when the product is instal

Página 36 - Pressure Loss (psi) )

Manual - Rinnai Condensing Water Heaters 41 What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that i

Página 37

42 Manuel – Rinnai Condensing Water Heaters — Ne pas entreposer ni utiliser d'essence ou ni d'autres vapeurs ou liquides inflammables à p

Página 38

Manuel – Rinnai Condensing Water Heaters 43 Comportements et pratiques de sécurité Réglage de température Instructi

Página 39

44 Manuel – Rinnai Condensing Water Heaters Plages de température avec un contrôleur de température Ce chauffe-eau va tenter de fournir de

Página 40 - Consumer Support

Manuel – Rinnai Condensing Water Heaters 45 AVERTISSEMENT Coupez l'alimentation électrique, et fermez l'arrivée de gaz et d'ea

Página 41

46 Manuel – Rinnai Condensing Water Heaters Seuls des installateurs qualifiés avec une formation adéquate peuvent installer cet appareil. La garanti

Página 42 - Enregistrer votre produit à

Manuel – Rinnai Condensing Water Heaters 47 to sideto frontto topto floor/ground Écartements par rapport à l'appareil 1. I

Página 43 - Brûlure

48 Manuel – Rinnai Condensing Water Heaters Installations à haute altitude Micro-commutateur 0-2000 ft (0-610 m) 2001-5200 ft (610-1

Página 44 - N° de micro

Manuel – Rinnai Condensing Water Heaters 49 Tuyauterie d'eau • Une vanne manuelle de coupure d'eau doit intercalée s

Página 45 - AVERTISSEMENT

Manual - Rinnai Condensing Water Heaters 5 The Rinnai water heater is one of the most advanced water heaters available. It provides a continuous

Página 46

50 Manuel – Rinnai Condensing Water Heaters GasSupply3/4"ColdWaterSupplyLine3/4" Hot Water Supply LineRinnaiEquipment ListRinnaiWater Heat

Página 47

Manuel – Rinnai Condensing Water Heaters 51 • Employez seulement le passage qui est approuvé et identifié comme acceptable pour les appareils de

Página 48

52 Manuel – Rinnai Condensing Water Heaters Nombre de coudes à 90° 0 1 2 3 4 5 6 41 ft 1 (12.5 m) 35 ft 2 (10.7 m) 29 ft 3 (8.8 m) 23 ft 4

Página 49

Manuel – Rinnai Condensing Water Heaters 53 Contacts avec les constructeurs de ventilation pour des informations d'installation et de liste d

Página 50

54 Manuel – Rinnai Condensing Water Heaters Espacement pour terminaison de cheminée (ANS Z21.10.3 ï CSA 4.3) INSIDECORNER DETAI LFIXEDCLOS

Página 51

Manuel – Rinnai Condensing Water Heaters 55 Fixez la pièce de ventilation connectée sur le chauffe-eau avec une vis autotaraudeuse dans le trou si

Página 52

56 Manuel – Rinnai Condensing Water Heaters Instructions d'utilisation À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ A

Página 53

Manuel – Rinnai Condensing Water Heaters 57 Diagramme en escalier PHASE NEUTRE CONTACT DE DÉTECTION DE GEL FUSIBLE 7 A ANTI-FOUD

Página 54

58 Manuel – Rinnai Condensing Water Heaters Support à la clientèle Qu'est-ce qui est couvert ? Cette garantie couvre tous défauts dus aux maté

Página 55

Manuel – Rinnai Condensing Water Heaters 59 Que fait Rinnai pour exercer la garantie ? Rinnai va réparer ou remplacer le produit, ou toute partie

Página 56

6 Manual - Rinnai Condensing Water Heaters Temperature Controllers - Models MC-91-1US & MCC-91-1US MC-502RC-1US-S * (Wireless) *

Página 57

Rinnai’s other fine products Rinnai America Corporation 103 International Drive Peachtree City, GA 30269 TOLL FREE: 1-800-621-9419 FAX: 678-829-1666 w

Página 58 - Support à la clientèle

Manual - Rinnai Condensing Water Heaters 7 MC-100V-1US BC-100V-1US The BC-100V controller is water resistant. Avoid splashing the controller. NOT

Página 59

8 Manual - Rinnai Condensing Water Heaters How to Set the Temperature 1. If the water heater is off, press the ON/OFF button to tur

Página 60 - Rinnai’s other fine products

Manual - Rinnai Condensing Water Heaters 9 Suggested temperatures are • Kitchen 120 ºF (49º C) • Shower 98º - 110º F (37º - 43º C) • Bath Fil